3-3
Cisco MWR 1900 Mobile Wireless Edge Router Hardware Installation Guide
78-13982-02
Chapter 3 Installing the Router
Connecting the Console Terminal and Modem
These ports provide administrative access to your router either locally (with a console terminal) or
remotely (with a modem).
Identifying a Rollover Cable
Use a rollover cable to connect to the asynchronous serial console and auxiliary ports. You can identify
a rollover cable by comparing the two modular ends of the cable. Holding the cables side-by-side, with
the tab at the back, the wire connected to the pin on the outside of the left plug should be the same color
as the wire connected to the pin on the outside of the right plug. (See Figure 3-2.) If your cable came
from Cisco, pin 1 will be white on one connector, and pin 8 will be white on the other (a rollover cable
reverses pins 1 and 8, 2 and 7, 3 and 6, and 4 and 5).
Figure 3-2 Identifying a Rollover Cable
Console Port
Take the following steps to connect a terminal or a PC running terminal emulation software to the
console port on the router:
Step 1 Connect the terminal using an RJ-45 rollover cable and an RJ-45-to-DB-25 or RJ-45-to-DB-9 adapter
(labeled TERMINAL).
Note The RJ-45-to-DB-25 adapter (Cisco part number 29-0810-01) can be purchased
from Cisco.
Step 2 Configure your terminal or terminal emulation software for 9600 baud, 8 data bits, no parity, and 2 stop
bits.
Pin 1
Pin 8
H3824
Pin 1 and pin 8
should be the
same color