1-141
Cisco Media Gateway Controller Software Release 9 Billing Interface Guide
OL-1089-11
Chapter 1 Billing Interfaces
CDE Detail Description
Meter Pulses Received (Tag: 4213)
Meter Pulses Sent (Tag: 4214)
Table 1-157 Meter Pulses Received Description Form
Name: Meter Pulses Received Tag: 4213 Source: MDL
Description/Purpose: Contains the total number of meter pulses received at the terminating side of the call.
Format: BE Length in Octets: 4
Data Value: Integer value in the range: 0 to 2
32
-1
Extended Data Value: No extended value.
General Information:
MGC Release: Release 9.5(2) and later.
Table 1-158 Meter Pulses Sent Description Form
Name: Meter Pulses Sent Tag: 4214 Source: MDL
Description/Purpose: Contains the total number of meter pulses sent to the originating side of the call.
Format: BE Length in Octets: 4
Data Value: Integer value in the range: 0 to 2
32
-1
Extended Data Value: No extended value.
General Information: The total pulses comprise those meter pulses generated internally and those transitted by the MGC.
MGC Release: Release 9.5(2) and later.