Cisco Systems 10005 ESR Instalační manuál Strana 7

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 26
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 6
7
Cisco 10005 ESR DC Power Entry Module Installation
78-12653-01
Prerequisites and Preparation
Required Tools and Equipment
Table 1 lists the tools and equipment you need to install a DC PEM.
Table 1 Tools and Equipment
Quantity Description Comments
1 Antistatic wrist or ankle strap
with connection cord
Prevents damage to equipment
from electrostatic discharge
(ESD).
1 Number 2 phillips screwdriver
1 Flat-blade screwdriver. We
recommend a torque-limiting
screwdriver.
Blade should measure 1.0 mm
thick by 4.0 mm wide. An
appropriate screwdriver is
available from Phoenix Contact
Inc. of Harrisburg, PA, USA.
1 Wire stripping tool Choose a tool that does not nick
the internal wire.
2 or 4 Tie wraps
1 Metric measuring tape or ruler
1 Marking pen
1 Voltmeter
3 or 6
(length
varies)
6 AWG (recommended) copper
wires long enough to reach from
the Cisco 10005 chassis to the
DC power source.
Three wires (two power, one
ground) are needed for a
single DC power source.
Six wires (four power, two
ground) are needed for two
DC power sources.
The wires must meet these
specifications:
Conductor size 6 AWG or
8 AWG (6 AWG preferred)
Diameter:
Minimum: 3.38 mm
Maximum: 4.52 mm
Multistranded copper
construction
Zobrazit stránku 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 25 26

Komentáře k této Příručce