Cisco Systems ONS 15310-CL Průvodce řešením problémů Strana 100

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 334
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 99
1-66
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Chapter 1 General Troubleshooting
1.10.4 Circuit Creation Error with VT1.5 Circuit
1.10.4 Circuit Creation Error with VT1.5 Circuit
Symptom You might receive an “Error while finishing circuit creation. Unable to provision circuit.
Unable to create connection object at node-name” message when trying to create a VT1.5 circuit in CTC.
Table 1-23 describes the potential causes of the symptom and the solutions.
1.10.5 OC-3 and DCC Limitations
Symptom There are limitations to OC-3 and DCC usage.
Table 1-24 describes the potential cause of the symptom and the solution.
Table 1-23 Circuit Creation Error with VT1.5 Circuit
Possible Problem Solution
You might have run out
of bandwidth on the VT
cross-connect matrix at
the node indicated in the
error message.
The ONS 15310-CL matrix has a maximum capacity of 336 bidirectional
VT1.5 cross-connects. The ONS 15310-MA capacity is 1,064.
Table 1-24 OC-3 and DCC Limitations
Possible Problem Solution
OC-3 and DCC have
limitations for the
system.
For an explanation of OC-3 and DCC limitations, refer to the “DCC
Tunnels” section in the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Procedure Guide.