Cisco Systems UCS C210 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Servery Cisco Systems UCS C210. Cisco Systems UCS C210 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 104
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Cisco UCS C210 Server
Installation and Service Guide
Covers UCS C210 Server Generations M1 and M2
July 31, 2013
Text Part Number: OL-20887-02
Zobrazit stránku 0
1 2 3 4 5 6 ... 103 104

Shrnutí obsahu

Strany 1 - Cisco UCS C210 Server

Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706 USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax:

Strany 2

xCisco UCS C210 Server Installation and Service GuideOL-20887-02AvisoINSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Voc

Strany 3 - CONTENTS

C-6Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix • The prompt for the mezzanine-style controller cards is Ctrl-C. • The

Strany 4 - Contents

C-7Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix For More Information The LSI utilities have help documentation for more i

Strany 5

C-8Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix

Strany 6

D-1Cisco UCS C210 Server Installation and Service GuideOL-20887-02APPENDIXDInstallation for Cisco UCS IntegrationThe Cisco UCS integration instructi

Strany 7 - Organization

D-2Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix

Strany 8 - Conventions

xiCisco UCS C210 Server Installation and Service GuideOL-20887-02AvisoINSTRUÇÕES IMPORTANTES DE SEGURANÇAEste símbolo de aviso significa perigo. Voc

Strany 9 - Avvertenza

xiiCisco UCS C210 Server Installation and Service GuideOL-20887-02

Strany 10 - Varning!

xiiiCisco UCS C210 Server Installation and Service GuideOL-20887-02Obtaining Documentation and Submitting a Service RequestFor information on obtain

Strany 11 - Advarsel

xivCisco UCS C210 Server Installation and Service GuideOL-20887-02

Strany 12

CHAPTER 1-1Cisco UCS C210 Server Installation and Service GuideOL-20887-021Overview The Cisco UCS C210 Server, which is a part of the Cisco UCS C-Ser

Strany 13

1-2Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 1-2 Rear Panel Features The Cisco UCS C210 server has the following

Strany 14

1-3Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Disk ManagementFactory-configured RAID5 support options: • RAID 0 and 1 s

Strany 15 - Overview

1-4Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter See the “Technical Specifications” section on page A-1 for more physical,

Strany 16 - Chapter

CHAPTER 2-1Cisco UCS C210 Server Installation and Service GuideOL-20887-022Installing the Server This chapter describes how to install the server and

Strany 17

THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECO

Strany 18

2-2Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Unpacking and Inspecting the Server Tip Keep the shipping container in cas

Strany 19 - Installing the Server

2-3Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Preparing for Installation This section includes the following topics: •

Strany 20

2-4Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Rack Requirements This section provides the requirements for the standard

Strany 21 - Preparing for Installation

2-5Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing the Server Into a RackThe qualified and supported part numbers

Strany 22 - Slide Rail Adjustment Range

2-6Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 2-2 Attaching a Slide-Rail AssemblyNote The mounting pegs that prot

Strany 23 - Statement 1006

2-7Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter d. Attach the second slide-rail assembly to the opposite side of the rack.

Strany 24

2-8Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter b. Push the server into the slide rails until it stops at the internal sto

Strany 25

2-9Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Initial Server SetupThis section contains the following topics: • Connect

Strany 26

2-10Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Step 2 Use the supplied KVM cable to connect a keyboard and VGA monitor t

Strany 27 - Initial Server Setup

2-11Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter d. Use this utility to change the NIC redundancy to your preference. This

Strany 28

iiiCisco UCS C210 Server Installation and Service GuideOL-20887-02CONTENTSPreface viiRelated Documentation viiAudience viiOrganization

Strany 29

2-12Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter NIC Modes and NIC Redundancy SettingsThis server has the following NIC mo

Strany 30

2-13Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter System BIOS and CIMC FirmwareThis section contains information about the

Strany 31 - System BIOS and CIMC Firmware

2-14Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Accessing the System BIOS You can change the BIOS settings for your serve

Strany 32 - Accessing the System BIOS

2-15Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Motherboard JumpersThese jumpers are adjacent to the CMOS battery (see Fi

Strany 33 - Motherboard Jumpers

2-16Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Using the BIOS Recovery Jumper J1E5 to Recover Corrupt BIOSThis jumper is

Strany 34

2-17Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Clearing the CIMC Admin Password Using Jumper J45 This procedure describe

Strany 35

2-18Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Using the Clear CMOS Jumper J1E6 You can use this jumper (see Figure 2-6

Strany 36

2-19Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Clearing the BIOS Admin Password Using Jumper J1E4 This procedure describ

Strany 37

2-20Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter

Strany 38

CHAPTER 3-1Cisco UCS C210 Server Installation and Service GuideOL-20887-023Maintaining the ServerThis chapter describes how to diagnose hardware prob

Strany 39 - Maintaining the Server

ContentsivCisco UCS C210 Server Installation and Service GuideOL-20887-02Status LEDs 3-2Front Panel LEDs 3-2Rear Panel LEDs 3-4Prepari

Strany 40 - Status LEDs

3-2Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Status LEDs This section describes the locations and interpretations of LE

Strany 41

3-3Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter System fault • Green—The server is operating properly. • Amber, blinkin

Strany 42 - Rear Panel LEDs

3-4Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Rear Panel LEDs Figure 3-2 shows the names and locations of the rear panel

Strany 43

3-5Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Ta b l e 3-2 Rear Panel LEDs LED Name StatePower supply fault • Off—No

Strany 44

3-6Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Note The 10/100/1000 Gigabit Ethernet link status LED and the speed LED mu

Strany 45

3-7Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Preparing for Component InstallationThis section describes how to prepare

Strany 46

3-8Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Shutting Down and Powering Off the ServerTip If you have ordered a server

Strany 47

3-9Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Removing and Replacing the Server in a Rack To remove or replace the serve

Strany 48 - Statement 14

3-10Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Removing and Replacing the Server Top Cover To remove or replace the top

Strany 49

3-11Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Removing and Replacing the Server Front Cover Note It is not necessary to

Strany 50

ContentsvCisco UCS C210 Server Installation and Service GuideOL-20887-02APPENDIX B Cable and Power Cord Specifications B-1KVM Cable B-1Supp

Strany 51

3-12Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Replaceable Component Locations This section shows the locations of the c

Strany 52

3-13Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing or Replacing ComponentsWarningThis unit might have more than o

Strany 53

3-14Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing Hard Drives and Solid State Drives The qualified and supported

Strany 54 - Installing Power Supplies

3-15Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter To replace or install a hot-pluggable hard drive or SSD, follow these ste

Strany 55 - Installing a DVD Drive

3-16Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing Power Supplies The qualified and supported part numbers for th

Strany 56

3-17Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing a DVD Drive The qualified and supported part numbers for this

Strany 57 - Installing a Fan Tray

3-18Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter g. Replace the server in the rack, replace power cords and any other cabl

Strany 58

3-19Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing a Fan Tray The qualified and supported part numbers for this c

Strany 59 - Installing DIMMs

3-20Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 3-10 Removing and Replacing a Fan Tray1 Fan tray 2 Fan tray securi

Strany 60 - Rear of Server

3-21Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing DIMMs This section includes the following sections: • Memory

Strany 61 - Memory Population Rules

ContentsviCisco UCS C210 Server Installation and Service GuideOL-20887-02

Strany 62 - Memory Mirroring and RAS

3-22Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 3-11 Physical Representation of Banks and ChannelsFigure 3-12 show

Strany 63

3-23Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Memory Population RulesWhen considering the memory configuration of your

Strany 64 - CPU Replacement Procedure

3-24Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Memory Mirroring and RAS • The CPUs support memory mirroring only when C

Strany 65

3-25Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 3-13 Removing and Replacing Memory Modules1 DIMM slots (12) 2 DIMM

Strany 66

3-26Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing CPUs and Heatsinks The qualified and supported part numbers fo

Strany 67 - Statement 1015

3-27Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter f. Loosen the two captive screws that hold the heatsink to the chassis po

Strany 68

3-28Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 3-14 Removing and Replacing CPUs and Heatsinks1 Captive heatsink s

Strany 69

3-29Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing a Motherboard CMOS Battery WarningThere is danger of explosion

Strany 70

3-30Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 3-15 Removing and Replacing a Motherboard CMOS BatteryInstalling a

Strany 71

3-31Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Step 2 Install a TPM:a. Align the connector that is on the underside of t

Strany 72 - Replacing a PCIe Card

viiCisco UCS C210 Server Installation and Service GuideOL-20887-02PrefaceThis preface describes the audience, organization, and conventions of the C

Strany 73

3-32Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter On the BIOS utility screen, select the Security tab, then select Set Admi

Strany 74

3-33Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter b. Set the assembly in place, aligning the riser cards with the PCIe slot

Strany 75

3-34Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Replacing a PCIe Card This section contains the following topics: • Repl

Strany 76

3-35Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Note Older servers have a screw that secures the PCIe riser to the rear o

Strany 77

3-36Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 3-19 Removing and Replacing a PCIe Card1 Riser card assembly remov

Strany 78 - The SAS Expander

3-37Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Special Considerations for the Cisco UCS P81E Virtual Interface Card (N2X

Strany 79

3-38Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing Multiple PCIe Cards and Resolving Limited ResourcesWhen a larg

Strany 80 - [Statement 1015]

3-39Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Resolving Insufficient 16-Bit I/O Space The system has only 64 KB of lega

Strany 81

3-40Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Replacing a SAS Extender or SAS ExpanderThis server has two factory-confi

Strany 82 - Installing a Mezzanine Card

3-41Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Replacing a SAS Extender or SAS Expander CardTo replace a SAS extender or

Strany 83

viiiCisco UCS C210 Server Installation and Service GuideOL-20887-02Conventions This document uses the following conventions for notes, cautions, and

Strany 84

3-42Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Replacing an LSI MegaRAID Battery Backup UnitWhen you install an LSI Mega

Strany 85 - Technical Specifications

3-43Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 3-22 Removing and Replacing an LSI BBU1 Cable access opening 2 Sec

Strany 86 - Power Specifications

3-44Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Installing a Mezzanine Card The qualified and supported part numbers for

Strany 87 - KVM Cable

3-45Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter Figure 3-23 Removing and Replacing a Mezzanine Card1 Mezzanine card retai

Strany 88

3-46Cisco UCS C210 Server Installation and Service GuideOL-20887-02Chapter

Strany 89 - AC Power Cord Illustrations

A-1Cisco UCS C210 Server Installation and Service GuideOL-20887-02APPENDIXATechnical SpecificationsThis appendix lists the technical specifications

Strany 90 - Figure B-6 SFS-250V-10A-ID

A-2Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix Environmental Specifications Table A-2 lists the environmental specificat

Strany 91 - Figure B-9 CAB-9K10A-SW

B-1Cisco UCS C210 Server Installation and Service GuideOL-20887-02APPENDIXBCable and Power Cord SpecificationsThis appendix provides cabling and por

Strany 92 - Figure B-12 CAB-N5K6A-NA

B-2Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix Supported Power Cords and Plugs Each power supply has a separate power co

Strany 93 - Figure B-13 CAB-9K12A-NA

B-3Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix AC Power Cord IllustrationsThis section contains the AC power cord illust

Strany 94

ixCisco UCS C210 Server Installation and Service GuideOL-20887-02VaroitusTÄRKEITÄ TURVALLISUUSOHJEITATämä varoitusmerkki merkitsee vaaraa. Tilanne v

Strany 95

B-4Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix Figure B-4 SFS-250V-10A-CNFigure B-5 CAB-9K10A-EUFigure B-6 SFS-250V-10A-

Strany 96

B-5Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix Figure B-7 SFS-250V-10A-ISFigure B-8 CAB-9K10A-ITFigure B-9 CAB-9K10A-SWC

Strany 97 - RAID Controller Cabling

B-6Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix Figure B-10 CAB-9K10A-UKFigure B-11 CAB-AC-250V/13AFigure B-12 CAB-N5K6A-

Strany 98

B-7Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix Figure B-13 CAB-9K12A-NAFigure B-14 CAB-C13-C14-JMPR, Jumper Power Cord C

Strany 99 - Release 1.2(1)

B-8Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix

Strany 100

C-1Cisco UCS C210 Server Installation and Service GuideOL-20887-02APPENDIXCRAID Controller ConsiderationsThis appendix contains the following sectio

Strany 101 - For More Information

C-2Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix Enabling the Integrated Intel ICH10R RAID Controller in the BIOSNote The

Strany 102 - Appendix

C-3Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix Enabling the Mezzanine Card RAID Controller in the BIOSWhen using the sup

Strany 103 - APPENDIX

C-4Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix In some cases, the default extender backplane requires different cables t

Strany 104

C-5Cisco UCS C210 Server Installation and Service GuideOL-20887-02Appendix How to Disable Quiet Boot for CIMC Firmware Earlier Than Release 1.2(1)Fo

Komentáře k této Příručce

Žádné komentáře